-
Grooved Check Valve
The TYCO Model CV-1F Grooved End Swing Check Valves are compact and rugged swing-type units that allow water flow in one direction and prevent flow in the opposite direction.
View Product Datasheet
QR 525.00 – QR 1,245.00View Options -
Wet Alarm Valves
The TYCO Model Alarm Check Valves are intended for use in wet pipe (automatic sprinkler) fire protection systems.
View Product Datasheet
-
Discharge Nozzle Brass
FM-200® is distributed within the protected area by the discharge nozzle which is sized to ensure the correct flow of agent for the risk. Nozzles are supplied as standard in Brass as BSPP or NPT with Stainless Steel as an option
View Product Datasheet
QR 345.00View Options -
FIVC Expansion Joint -Threaded
FIVC Expansion Joint is designed to be installed into pipelines for the purpose to avoid damage caused by stretching, compressing, deflecting, or displacing pipes.
View Product Datasheet EPDM02
QR 43.00View Options -
FIVC Butterfly Valve – ...
FIVC Wafer Butterfly Valve is designed to be installed in pipelines for isolating or regulating purposes. With its high-quality rotational disc, the valve features a quick shut-off function.
View Product Datasheet
QR 1,012.00 – QR 5,671.00View Options -
FIVC Butterfly Valve – ...
FIVC Lugged Butterfly Valve with its replaceable seat is designed to be installed in pipelines for isolating or regulating purposes. With its high-quality rotational disc, the valve features a quick shut-off function.
View Product Datasheet
QR 1,709.00 – QR 5,031.00View Options -
Flowcon Bronze Y Strainers
FIVC Y-Strainer is designed to collect and prevent solid impurities from entering the pipeline that can cause malfunction and damage to the most sensitive plant components such as pumps, control valves, flow, and heat meters.
View Product Datasheet 260121
-
Upright Sprinkler
The TYCO Series TY-B, 5.6 K-factor, Upright (TY315) Sprinklers are standard response, standard coverage, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, commercial occupancies such as banks, hotels, shopping malls, factories, refineries, and chemical plants.
- All hazard
- Discharges a hemispherical water spray pattern in the area beneath the sprinkler
- Small frame, narrow profile bulb
- Designed for use in light, ordinary, or extra hazard, commercial occupancies such as banks, hotels, shopping malls, factories, refineries, chemical plants, etc.
View Product Datasheet
QR 24.40View Options -
Sidewall Sprinkler
The TYCO Series TY 5.6 K-factor, Horizontal Sidewall Sprinklers are standard response, standard coverage decorative 5 mm glass bulb type spray sprinklers designed for use in light and ordinary hazard, commercial occupancies such as banks, hotels, and shopping malls.
- Light hazard/Ordinary hazard
- Small frame
- Unique deflector design of the horizontal sidewall sprinkler results in smaller profile
- Designed for installation along a wall or the side of a beam just beneath a smooth ceiling
- Water discharge is directed primarily outward and downward in a quarter spherical pattern
- Sidewall sprinklers are often used in lieu of standard pendent or upright sprinklers due to building construction, economic considerations, or aesthetics
- Special deflector on the vertical sidewall sprinkler allows it to be installed in either a pendent or upright position
View Product Datasheet
QR 29.00View Options -
Butterfly Valve Grooved End
The TYCO Models BFV-300 and BFV300C Grooved End Butterfly Valves are indicating type valves designed for use in fire protection systems where a visual indication of open or closed valve condition is required
- Designed for use in fire protection systems
- UL and ULC Listed
- FM Approved
View Product Datasheet
QR 756.00 – QR 1,435.00View Options -
Hose Male Adaptor
The male pilot hose connector is used to connect two pilot hoses together for systems where a second container of a different size is used to protect a different enclosure.
View Product Datasheet
-
Manual/Pneumatic Actuator
This Actuator is Used for mechanical or pneumatic operating system at the container position and is fitted to the top of the valve assembly or removable electrical actuator.
View product Datasheet
QR 334.00View Options -
Supervisory Pressure Switch
A low pressure warning switch is fitted to every container and must be ordered separately. The device continuously monitors the container pressure and in the event of the pressure dropping below 20 bar (290 psi) the switch operates to enable the condition to be signaled to a control unit
View Product Datasheet
QR 157.00View Options -
Manifold Inlet
Manifold inlets are available for the construction of system manifolds. Threaded Inlet for Manifolds
View Product Datasheet
-
Balancing Valves Variable Ori...
FIVC Static Balancing Valve is designed with integrated pressure probes to determine the flow rate through the integrated fixed orifice.
View Product Datasheet
QR 630.00View Options -
Bladder Expansion Tank
Intended for use in hydronic heating systems, these tanks accept the expanded volume of hot water keeping the system pressure below the relief valve setting, thus preventing dangerous pressure build-up.
View Product Datasheet
QR 12,200.00 – QR 13,500.00View Options -
Roof Exhaust Downblast
FCS -D (Direct drive) & FCS -B (Belt drive) fans are ideal for general purpose exhaust applications including bathrooms, garages, general kitchen areas, offices, churches, dormitories, factories, large warehouses, and other relatively clean air applications. They feature a weather-resistant, seamless spun aluminum housing which works in conjunction with a patented wheel design and deeply spun inlets to provide smooth quiet airflow through the ventilator. The centrifugal wheels are aluminum, non-overloading, backward inclined, robotically welded, and dynamically balanced
View Product Datasheet
-
Plate Mounted Axial Fans
The QCM series are axial fans suitable for application on wall or panel in residential, commercial and industrial building.
View Product Datasheet
QR 2,487.00 – QR 2,896.00View Options -
Trim Vertical Closed Drain Co...
The TYCO Series “Royal Flush II” Concealed Pendent Sprinklers Quick Response (3-mm bulb) and Standard Response (5-mm bulb), are decorative sprinklers featuring a flat cover plate designed to conceal the sprinkler.
The TYCO Model RC-1 Retard Chamber is required in installations that will be subject to pressure variations, as are generally associated with public water supplies, in order to help prevent false alarms.
- Quick & Standard Response, Standard Coverage
- Designed to conceal the sprinkler.
- UL Listed and FM Approval
View Product Datasheet RFII
-
Gravity Shutters
Gravity Shutters avoids heat loss and entry of wind, rain, and birds. The fins of the shutter are opened by the airflow when the fan is working and they close down by gravity when the fan is switched off.
View Product Datasheet
-
Concealed Pendent Sprinkler
The TYCO Series RFII 5.6 K-factor, “Royal Flush II” Concealed Pendent Standard Response (5-mm bulb), is a decorative sprinkler featuring a flat cover plate designed to conceal the sprinkler. These sprinklers are optimal for architecturally sensitive areas such as hotel lobbies, office buildings, churches, and restaurants.
Each sprinkler includes a Cover Plate/Retainer Assembly and a Sprinkler/Support Cup Assembly.
View Product Datasheet
QR 32.00 – QR 48.00View Options -
Pendent Sprinkler
The TYCO Series TY-B, 5.6 K-factor, Pendent (TY325) Sprinklers are standard response, standard coverage, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, commercial occupancies such as banks, hotels, shopping malls, factories, refineries, and chemical plants.
View Product Datasheet TY3251
QR 23.00 – QR 30.00View Options