-
Grooved Check Valve
The TYCO Model CV-1F Grooved End Swing Check Valves are compact and rugged swing-type units that allow water flow in one direction and prevent flow in the opposite direction.
View Product Datasheet
-
Wet Alarm Valves
The TYCO Model Alarm Check Valves are intended for use in wet pipe (automatic sprinkler) fire protection systems.
View Product Datasheet
-
Upright Sprinkler
The TYCO Series TY-B, 5.6 K-factor, Upright (TY315) Sprinklers are standard response, standard coverage, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, commercial occupancies such as banks, hotels, shopping malls, factories, refineries, and chemical plants.
- All hazard
- Discharges a hemispherical water spray pattern in the area beneath the sprinkler
- Small frame, narrow profile bulb
- Designed for use in light, ordinary, or extra hazard, commercial occupancies such as banks, hotels, shopping malls, factories, refineries, chemical plants, etc.
View Product Datasheet
-
Sidewall Sprinkler
The TYCO Series TY 5.6 K-factor, Horizontal Sidewall Sprinklers are standard response, standard coverage decorative 5 mm glass bulb type spray sprinklers designed for use in light and ordinary hazard, commercial occupancies such as banks, hotels, and shopping malls.
- Light hazard/Ordinary hazard
- Small frame
- Unique deflector design of the horizontal sidewall sprinkler results in smaller profile
- Designed for installation along a wall or the side of a beam just beneath a smooth ceiling
- Water discharge is directed primarily outward and downward in a quarter spherical pattern
- Sidewall sprinklers are often used in lieu of standard pendent or upright sprinklers due to building construction, economic considerations, or aesthetics
- Special deflector on the vertical sidewall sprinkler allows it to be installed in either a pendent or upright position
View Product Datasheet
-
Butterfly Valve Grooved End
The TYCO Models BFV-300 and BFV300C Grooved End Butterfly Valves are indicating type valves designed for use in fire protection systems where a visual indication of open or closed valve condition is required
- Designed for use in fire protection systems
- UL and ULC Listed
- FM Approved
View Product Datasheet
-
Fire Hose Reel
A standard 25mm fixed hose reel, capable of holding 30m of 25mm fire hose. Manually turn on water supply, pull out fire hose to required length and open jet spray nozzle.
View Product Datasheet
QR 845.00View Options -
Roof Exhaust Downblast
FCS -D (Direct drive) & FCS -B (Belt drive) fans are ideal for general purpose exhaust applications including bathrooms, garages, general kitchen areas, offices, churches, dormitories, factories, large warehouses, and other relatively clean air applications. They feature a weather-resistant, seamless spun aluminum housing which works in conjunction with a patented wheel design and deeply spun inlets to provide smooth quiet airflow through the ventilator. The centrifugal wheels are aluminum, non-overloading, backward inclined, robotically welded, and dynamically balanced
View Product Datasheet
-
Plate Mounted Axial Fans
The QCM series are axial fans suitable for application on wall or panel in residential, commercial and industrial building.
View Product Datasheet
QR 2,487.00 – QR 2,896.00View Options -
Trim Vertical Closed Drain Co...
The TYCO Series “Royal Flush II” Concealed Pendent Sprinklers Quick Response (3-mm bulb) and Standard Response (5-mm bulb), are decorative sprinklers featuring a flat cover plate designed to conceal the sprinkler.
The TYCO Model RC-1 Retard Chamber is required in installations that will be subject to pressure variations, as are generally associated with public water supplies, in order to help prevent false alarms.
- Quick & Standard Response, Standard Coverage
- Designed to conceal the sprinkler.
- UL Listed and FM Approval
View Product Datasheet RFII
QR 1,260.00View Options -
Gravity Shutters
Gravity Shutters avoids heat loss and entry of wind, rain, and birds. The fins of the shutter are opened by the airflow when the fan is working and they close down by gravity when the fan is switched off.
View Product Datasheet
-
Concealed Pendent Sprinkler
The TYCO Series RFII 5.6 K-factor, “Royal Flush II” Concealed Pendent Standard Response (5-mm bulb), is a decorative sprinkler featuring a flat cover plate designed to conceal the sprinkler. These sprinklers are optimal for architecturally sensitive areas such as hotel lobbies, office buildings, churches, and restaurants.
Each sprinkler includes a Cover Plate/Retainer Assembly and a Sprinkler/Support Cup Assembly.
View Product Datasheet
QR 32.00 – QR 48.00View Options -
Pendent Sprinkler
The TYCO Series TY-B, 5.6 K-factor, Pendent (TY325) Sprinklers are standard response, standard coverage, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, commercial occupancies such as banks, hotels, shopping malls, factories, refineries, and chemical plants.
View Product Datasheet TY3251
-
-
Centrifugal Roof Extractors
Centrifugal roof fans are designed for direct or ducted ventilation in residential, commercial, and industrial buildings. they are designed for easy installation, high-efficiency low noise levels. The motor is outside the airflow, this allows the fan to exhaust clean or slightly dusty air with temperature
View Product Datasheet
QR 2,296.00View Options -
Deluge Valve, Diaphragm Style
The DV-5 Deluge Valve is a diaphragm style valve that depends upon water pressure in the Diaphragm Chamber to hold the Diaphragm closed against the water supply pressure. These valves are to be used only for hydraulically calculated systems.
View Product Datasheet
QR 3,882.00View Options -
Centrifugal In-Line Fans Roun...
The AXC LINE-METAL is a series of centrifugal in-line fans with the advantage, typical of axial fans, to convey air along the same axis of the impeller
View Product Datasheet
QR 372.00View Options -
Inlet Cone
It allows a higher fan efficiency in case of installation with an inlet or outlet not ducted. Manufactured in steel sheet, with one flange according to UNI ISO6580 – EUROVENT to be fitted to the CC fan, and an aerodynamically shaped bell mouth, with fixing holes for a protection guard Protected against atmospheric agents by epoxy paint.
View Product Datasheet
-
Extended Coverage Horizontal ...
TYCO Series Extended Coverage Horizontal Sidewall Sprinklers Quick and Standard Response (Light Hazard) are decorative 3 mm glass bulb type spray sprinklers designed for use in hydraulically calculated sprinkler systems in light hazard, commercial application
View Product Datasheet
QR 40.00 – QR 45.00View Options -
Ultra-Slim Wall Axial Fans
To exhaust air directly to the outside or into a short length ducting (max 3 m length). Suitable for toilets, bathrooms, WC’s, shower-rooms, utility rooms, and kitchens
View Product Datasheet
QR 95.00 – QR 194.00View Options