-
Carrier Wall split unit 1.5 t...
High Wall split unit , 2 TR / 6 star / R-410 a refrigerant / Rotary Compressor View Product Datasheet
QR 2,280.00 – QR 2,850.00View Options -
Carrier Wall split unit 2.5 ton
High Wall split unit Model No 38KHB030HN/42KHB030HN , 2.5TR / 6 star / R-410 a refrigerant / Rotary Compressor View Product Datasheet
QR 3,925.00View Options -
Ducted Split Air Conditioner
Low height air handler with side-discharge condensing unit Anti-freeze temperature sensor is provided on the coil against freezing during abnormal operating conditions.
Microprocessor Based Controller Filter drier is supplied loose as standard accessory Removable panels at the bottom of the unit that are provided for service access .
Quick connector for interconnecting communication cable (10 meter Long) from main controller to Controller User Interface Metallic Condenser fan blades and evaporator blower ensure safety & high durability .
High Pressure and Low Pressure safety controls are a standard feature on all the models
2T,2.5T,3T,3.5T Download Brochure
-
Wall Split Air Conditioner
Developed with environment friendly R410A refrigerant. R410A refrigerant is highly efficient and has an Ozone Depletion Potential (ODP) of 0.
Super Quiet: The in-built additional temperature sensor in the remote controller monitors the surrounding temperature. Therefore, the air-conditioner can adjust the room temperature more accurately and provide extra comfort to users.Quality rating : 6 star
- Inner-grooved copper tube
- Safety Design
- Leakage Detection
- Sleep Mode
- Vector Precision Air Supply
- T3 Tropical Compressor T3 Tropical Rotary compressor for high-efficiency and operation up to 52°C
Rust-proof - Flanging Processed Plate Metal
- Valve Protection Cover
Introduction Download Brochure
Performance table & selection Download Brochure
-
Rubber Insulation For Duct – ...
ARMAFLEX CLASS O (AC) RUBBER INSULATION
Insulation/protection to control condensation, reduce energy loss and protect against frost for air ducts, vessels (incl. elbows, fittings, flanges, etc). Suitable for air HVAC Ducts and is available in various thicknesses & options with and without factory-applied self-adhesive property.
View Product Datasheet
-
Rubber Insulation for Pipe – ...
ARMAFLEX RUBBER INSULATION CLASS O (AC)
Insulation/protection to control condensation, reduce energy loss and protect against frost on pipes, air ducts, vessels (incl. elbows, fittings, flanges, etc). Suitable for hot and cold water services, chilled water lines, heating systems, air conditioning, and refrigerated pipework
Note : Standard 2 meter length unit Qty , Price is per Mtr
View Product Datasheet
-
Rubber Insulation for Pipe -AP
ARMAFLEX AP RUBBER INSULATION
Armaflex AP Insulation/protection to control condensation, reduce energy loss and protect against frost on pipes, air ducts, vessels (incl. elbows, fittings, flanges, etc). Suitable for hot and cold water services, chilled water lines, heating systems, air conditioning ductwork, and refrigerated pipework. This grade of Insulation has in build micro ban antimicrobial technology & has better fire properties and complies with ASTM E-84 standard.
Standard Length: 2 Mtr pc Qty ,Price is per Mtr.
View Product Datasheet
QR 10.15 – QR 31.53View Options -
Upright Sprinkler
The TYCO Series TY-B, 5.6 K-factor, Upright (TY315) Sprinklers are standard response, standard coverage, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, commercial occupancies such as banks, hotels, shopping malls, factories, refineries, and chemical plants.
- All hazard
- Discharges a hemispherical water spray pattern in the area beneath the sprinkler
- Small frame, narrow profile bulb
- Designed for use in light, ordinary, or extra hazard, commercial occupancies such as banks, hotels, shopping malls, factories, refineries, chemical plants, etc.
View Product Datasheet
-
Sidewall Sprinkler
The TYCO Series TY 5.6 K-factor, Horizontal Sidewall Sprinklers are standard response, standard coverage decorative 5 mm glass bulb type spray sprinklers designed for use in light and ordinary hazard, commercial occupancies such as banks, hotels, and shopping malls.
- Light hazard/Ordinary hazard
- Small frame
- Unique deflector design of the horizontal sidewall sprinkler results in smaller profile
- Designed for installation along a wall or the side of a beam just beneath a smooth ceiling
- Water discharge is directed primarily outward and downward in a quarter spherical pattern
- Sidewall sprinklers are often used in lieu of standard pendent or upright sprinklers due to building construction, economic considerations, or aesthetics
- Special deflector on the vertical sidewall sprinkler allows it to be installed in either a pendent or upright position
View Product Datasheet
-
Standard Air Louvers Model FAL
KMC Air Louvers are designed for both intake and exhaust air service for commercial & Industrial applications.
The fresh air louver is used to supply fresh air to the buildings or Air Handling Units (AHU).
Louvers are designed and manufactured for use in external applications.
Blades are fixed and at 45deg to protect against ingress of rain water.
View Product Datasheet
QR 48.00 – QR 209.00View Options -
Pressure Independent VAV unit...
KSQ terminals are AHRI Certified and are tested in accordance with AHRI Standard 880.
Optional factory installed electric heaters and integral sound attenuators for ultra-quiet performance are also available .
Note: The unit is supplied as a VAV box only . Controller and actuator to be provided by contractor .
View Product Datasheet
-
Curtain Fire Damper (UL 555 &...
The fire damper is intended to restrict the passage of flame; it shall consist of UL listed fusible link rated to 165˚F which shall release the curtain blades in the event of fire. The standard installation requires that the damper is positioned so that the closed plane of the blades is within the fire rated masonry/concrete barrier.
For non-standard construction & for more details consult our sales team.
QR 148.25 – QR 424.00View Options -
By-Pass VAV unit (Model: KME)
By-pass VAV terminals consist of a single primary air damper that shall proportion the total primary air through the terminal to either the ceiling plenum or the space as dictated by the space thermostat demand. These units are available with various casing materials & treatments with factory mounted actuators as required.
Note : The unit is supplied as VAV box only. Controller & actuator shall be provided by the contractor.
View Product Datasheet
-
Single Deflection Grilles (Mo...
Finish: Powder coated to RAL 9010 as standard. Other finish is available as option.
JMC Grilles and Registers have adjustable louvers and are available in single deflection models. The Single deflection grilles are designed to have one set of blades in the horizontal or vertical orientation. Air pattern is adjustable in one plane only. The Horizontal type provides the control over the deflection of the air pattern on adjustments whereas the vertical type provides the spread control of the air pattern reducing both throw and drop.
View Product Datasheet
QR 12.00 – QR 94.00View Options -
Sand Louvers Model KSTL
The Sand Trap Louvers Model KSTL are designed for usage in serving as a Pre – Filter element in dusty conditions. It has a degree of separation of sand and large dust particles, even in cases of high dust concentrations. The vertically arranged sections and holes for sand drainage ensure the sand trap louver is self- cleaning and maintenance free. The sand trap louver is designed to separate large particles at low air velocities, thus avoiding excessive dust loading on conventional plant filters. It is not intended as a substitute for conventional supply air filtration.
View Product Datasheet
-
Egg Crate Grilles (Model: KECG)
Finish: Powder coated to RAL 9010 as standard. Other finish is available as option.
JMC Return / Exhaust Grilles utilize core of cubical grid and mostly used where maximum free area is desired and “see through” is not a concern. These Grilles are typically used in ceiling applications where “see through” sight lines are minimized to directly below the grille. Recommended for general return or exhaust of room air.
View Product Datasheet
QR 28.00 – QR 233.00View Options -
Door Grille (Model: XNSA)
Finish: Powder coated to RAL 9010 as standard. Other finish is available as option.
KMC air transfer Grilles or Door grilles are typically used indoors and partitions to allow airflow to a space that is not directly served by a ducted source of supply air or a ducted outlet for return or exhaust air. These Door / Wall Grilles offer the largest free area possible with a complete sight proof or lightproof core.
View Product Datasheet
QR 32.00 – QR 210.00View Options -
Spot Diffuser (Model: SPD)
Finish: Powder coated to RAL 9010 as standard. Other finish is available as option.
KMC Spot diffusers are recommended for use in large spaces such as malls, exhibit hall, etc., Where directional control of conditioned air is of very much importance. The adjustable nozzle models make it possible to adapt the jet discharge angle to suit different operating conditions.
View Product Datasheet
-
Jet Diffuser (Model: KDJ)
Finish: Powder coated to RAL 9010 as standard. Other finish available as option.
JMC Jet diffuser is a high capacity diffuser with jet-type airflow specifically designed for spot heating or cooling in high ceiling applications. The elegant design is best suited for an architectural high-end appearance and provides a modern alternative to any traditional diffusers while upholding the trusted performance characteristics.
View Product Datasheet
QR 234.00 – QR 1,496.00View Options -
Cylinder Mounting Bracket
Vertical bracketing of the PCL-160, PCL-300 and PCL-460 is provided by the Model MB-15 bracket kit . Vertical bracketing of the PCL-600 is provided by the Model MB-1 bracket kit . These kits must be ordered separately with each cylinder/valve assembly. Cylinder installation instructions are provided in the installation section of this manual.
- Cylinder Bracket
- These kits must be ordered separately with each cylinder/valve assembly
- Cylinder installation instructions are provided in the installation section of this manual.
View Product Datasheet
-
Nozzle
Nozzles have been developed for appliance, plenum, and duct applications. All nozzles have a specific flow point value and are supplied with metal blow-off caps to prevent clogging. Each nozzle is stamped with the model number.
View Product Datasheet
-
Agent Cylinder With Valve
The cylinder is manufactured, tested, and meets DOT requirements. Cylinders come pre-filled with extinguishing agent and are charged with dry nitrogen to a pressure
- Meets the requirements of the Building Officials and Code Administrators (BOCA)
- Meets the requirements of the International Building Code (IBC)
- Approved by the City of New York Material and Equipment
View Product Datasheet
QR 2,445.00View Options