14Products found
View
Filter
  • Grooved Check Valve

    Brand: TYCO-CENTRAL

    The TYCO Model CV-1F Grooved End Swing Check Valves are compact  and rugged swing-type units that allow water flow in one direction and prevent flow in the opposite direction.

     

    View Product Datasheet

    View Options
  • Water Flow Switch

    Brand: POTTER

    The Potter VSR is a vane-type Waterflow switch with a non-corrosive insert for use on wet sprinkler systems.

    • The Potter VSR is a vane type water flow switch with non-corrosive insert for use on wet sprinkler systems.
    • It is UL Listed and FM Approved for use on steel pipe.
    • Non – corrosive sleeve factory installed in saddle

    View Product Datasheet

    QR 342.00QR 435.00
    View Options
  • Pressure Switch

    Brand: POTTER

    The Potter PS10 Series Pressure Actuated Switches are designed for the detection of a water flow condition in automatic fire sprinkler systems of particular designs such as wet pipe systems with alarm check valves, dry pipe, preaction, or deluge valves.

     

    View Product Datasheet

    View Options
  • Wet Alarm Valves

    Brand: TYCO-CENTRAL

    The TYCO Model Alarm Check Valves are intended for use in wet pipe (automatic sprinkler) fire protection systems.

     

    View Product Datasheet

    View Options
  • Tamper Switch

    Brand: POTTER

    The OSYSU is used to monitor the open position of an OS&Y (outside screw and yoke) type gate valve.

    The Model PCVS is a weather proof and tamper resistant switch for monitoring the open position of fire sprinkler control valves of the wall and yard post indicator and butterfly types

     

     

    View Product Datasheet     OSYSU      PCVS

    View Options
  • Upright Sprinkler

    Brand: Tyco

    The TYCO Series TY-B, 5.6 K-factor, Upright (TY315) Sprinklers are standard response, standard coverage, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, commercial occupancies such as banks, hotels, shopping malls, factories, refineries, and chemical plants.

    • All hazard
    • Discharges a hemispherical water spray pattern in the area beneath the sprinkler
    • Small frame, narrow profile bulb
    • Designed for use in light, ordinary, or extra hazard, commercial occupancies such as banks, hotels, shopping malls, factories, refineries, chemical plants, etc.

     

    View Product Datasheet

    View Options
  • Sidewall Sprinkler

    Brand: Tyco

    The TYCO Series TY 5.6 K-factor, Horizontal Sidewall Sprinklers are standard response, standard coverage decorative 5 mm glass bulb type spray sprinklers designed for use in light and ordinary hazard, commercial occupancies such as banks, hotels, and shopping malls.

    • Light hazard/Ordinary hazard
    • Small frame
    • Unique deflector design of the horizontal sidewall sprinkler results in smaller profile
    • Designed for installation along a wall or the side of a beam just beneath a smooth ceiling
    • Water discharge is directed primarily outward and downward in a quarter spherical pattern
    • Sidewall sprinklers are often used in lieu of standard pendent or upright sprinklers due to building construction, economic considerations, or aesthetics
    • Special deflector on the vertical sidewall sprinkler allows it to be installed in either a pendent or upright position

     

    View Product Datasheet    

    View Options
  • Butterfly Valve Grooved End

    Brand: TYCO-CENTRAL

    The TYCO Models BFV-300 and BFV300C Grooved End Butterfly Valves are indicating type valves designed for  use in fire protection systems where  a visual indication of open or closed  valve condition is required

    • Designed for use in fire protection systems
    • UL and ULC Listed
    • FM Approved

    View Product Datasheet

    View Options
  • Trim Vertical Closed Drain Co...

    Brand: TYCO-CENTRAL

    The TYCO Series  “Royal Flush II” Concealed Pendent  Sprinklers Quick Response (3-mm bulb) and Standard Response (5-mm  bulb), are decorative sprinklers featuring a flat cover plate designed to conceal the sprinkler.

    The TYCO Model RC-1 Retard Chamber is required in installations that will be subject to pressure variations, as are generally associated  with public water supplies, in order to help prevent false alarms.

    • Quick & Standard Response, Standard Coverage
    • Designed to conceal the sprinkler.
    • UL Listed and FM Approval

     

    View Product Datasheet         RFII

    QR 1,260.00
    View Options
  • Concealed Pendent Sprinkler

    Brand: Tyco

    The TYCO Series RFII 5.6 K-factor, “Royal Flush II” Concealed Pendent Standard Response (5-mm bulb), is a decorative sprinkler featuring a flat cover plate designed to conceal the sprinkler. These sprinklers are optimal for architecturally sensitive areas such as hotel lobbies, office buildings, churches, and restaurants.

    Each sprinkler includes a Cover Plate/Retainer Assembly and a Sprinkler/Support Cup Assembly.

     

    View Product Datasheet

    QR 32.00QR 48.00
    View Options
  • Pendent Sprinkler

    Brand: Tyco

    The TYCO Series TY-B, 5.6 K-factor, Pendent (TY325) Sprinklers are standard response, standard coverage, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, commercial occupancies such as banks, hotels, shopping malls, factories, refineries, and chemical plants.

     

    View Product Datasheet       TY3251

    View Options
  • Deluge Valve, Diaphragm Style

    Brand: TYCO-CENTRAL

    The DV-5 Deluge Valve is a diaphragm style valve that depends upon water pressure in the Diaphragm Chamber to hold the Diaphragm closed against the water supply pressure. These valves are to be used only for hydraulically calculated systems.

     

    View Product Datasheet

    QR 3,882.00
    View Options
  • Surge Protector

    Brand: Ditek

    DITEK’s DTK-HW Series of surge protective devices are designed and manufactured to meet the standards of the life safety industry and are widely used to protect fire alarm panels and other dedicated branch circuit loads.

     

    View Product Datasheet

     

    View Options
  • Extended Coverage Horizontal ...

    Brand: TYCO-CENTRAL

    TYCO Series Extended Coverage Horizontal Sidewall Sprinklers Quick and Standard Response (Light Hazard) are decorative 3 mm glass bulb type spray sprinklers designed for use in hydraulically calculated sprinkler systems in light hazard, commercial application

     

    View Product Datasheet

    QR 40.00QR 45.00
    View Options

Main Menu

💬 Need help?