OS and Y Gate Valves
Mueller 2300 Series Resilient Wedge Gate Valves are intended for use in potable water distribution or fire protection systems.
- UL 262 Listed and FM 1120/1130 Approved and certified to ANSI/NSF 61 & 372
- Epoxy Coated interior and exterior surfaces
- Outside Screw & Yoke (O.S.&Y)
- Adjustable packing
- Rubber encapsulated iron wedge
- Hand wheel – open left or open right
View Product Datasheet
-
Discharge Nozzle Brass
FM-200® is distributed within the protected area by the discharge nozzle which is sized to ensure the correct flow of agent for the risk. Nozzles are supplied as standard in Brass as BSPP or NPT with Stainless Steel as an option
View Product Datasheet
-
Upright Sprinkler
The TYCO Series TY-B, 5.6 K-factor, Upright (TY315) Sprinklers are standard response, standard coverage, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, commercial occupancies such as banks, hotels, shopping malls, factories, refineries, and chemical plants.
- All hazard
- Discharges a hemispherical water spray pattern in the area beneath the sprinkler
- Small frame, narrow profile bulb
- Designed for use in light, ordinary, or extra hazard, commercial occupancies such as banks, hotels, shopping malls, factories, refineries, chemical plants, etc.
View Product Datasheet
-
Sidewall Sprinkler
The TYCO Series TY 5.6 K-factor, Horizontal Sidewall Sprinklers are standard response, standard coverage decorative 5 mm glass bulb type spray sprinklers designed for use in light and ordinary hazard, commercial occupancies such as banks, hotels, and shopping malls.
- Light hazard/Ordinary hazard
- Small frame
- Unique deflector design of the horizontal sidewall sprinkler results in smaller profile
- Designed for installation along a wall or the side of a beam just beneath a smooth ceiling
- Water discharge is directed primarily outward and downward in a quarter spherical pattern
- Sidewall sprinklers are often used in lieu of standard pendent or upright sprinklers due to building construction, economic considerations, or aesthetics
- Special deflector on the vertical sidewall sprinkler allows it to be installed in either a pendent or upright position
View Product Datasheet
-
Cylinder Mounting Bracket
Vertical bracketing of the PCL-160, PCL-300 and PCL-460 is provided by the Model MB-15 bracket kit . Vertical bracketing of the PCL-600 is provided by the Model MB-1 bracket kit . These kits must be ordered separately with each cylinder/valve assembly. Cylinder installation instructions are provided in the installation section of this manual.
- Cylinder Bracket
- These kits must be ordered separately with each cylinder/valve assembly
- Cylinder installation instructions are provided in the installation section of this manual.
View Product Datasheet
-
Nozzle
Nozzles have been developed for appliance, plenum, and duct applications. All nozzles have a specific flow point value and are supplied with metal blow-off caps to prevent clogging. Each nozzle is stamped with the model number.
View Product Datasheet
-
Agent Cylinder With Valve
The cylinder is manufactured, tested, and meets DOT requirements. Cylinders come pre-filled with extinguishing agent and are charged with dry nitrogen to a pressure
- Meets the requirements of the Building Officials and Code Administrators (BOCA)
- Meets the requirements of the International Building Code (IBC)
- Approved by the City of New York Material and Equipment
View Product Datasheet
QR 2,445.00View Options -
Container Label
The container label detailsthe weight of NOVEC™ 1230 contained, empty weight, fill density and charge date.
View Product Datasheet
QR 286.00View Options -
Fire Hose Reel
A standard 25mm fixed hose reel, capable of holding 30m of 25mm fire hose. Manually turn on water supply, pull out fire hose to required length and open jet spray nozzle.
View Product Datasheet
QR 845.00View Options -
Hose Male Adaptor
The male pilot hose connector is used to connect two pilot hoses together for systems where a second container of a different size is used to protect a different enclosure.
View Product Datasheet
-
Manual/Pneumatic Actuator
This Actuator is Used for mechanical or pneumatic operating system at the container position and is fitted to the top of the valve assembly or removable electrical actuator.
View product Datasheet
QR 334.00View Options -
Manifold Inlet
Manifold inlets are available for the construction of system manifolds. Threaded Inlet for Manifolds
View Product Datasheet
QR 382.00View Options -
Concealed Pendent Sprinkler
The TYCO Series RFII 5.6 K-factor, “Royal Flush II” Concealed Pendent Standard Response (5-mm bulb), is a decorative sprinkler featuring a flat cover plate designed to conceal the sprinkler. These sprinklers are optimal for architecturally sensitive areas such as hotel lobbies, office buildings, churches, and restaurants.
Each sprinkler includes a Cover Plate/Retainer Assembly and a Sprinkler/Support Cup Assembly.
View Product Datasheet
QR 32.00 – QR 48.00View Options -
Pendent Sprinkler
The TYCO Series TY-B, 5.6 K-factor, Pendent (TY325) Sprinklers are standard response, standard coverage, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, commercial occupancies such as banks, hotels, shopping malls, factories, refineries, and chemical plants.
View Product Datasheet TY3251
-
Valve Single Tank Adaptors
When a single 343 litre container is being used without a manifold, three swivel adaptors are available for connection to the discharge outlet
View Product Datasheet
QR 657.00View Options