-
Pipe Insulation – Aluglass Faced
KIMMCO-ISOVER’s produces a wide range of glass wool-based pre-formed pipe sections; designed specifically for the insulation of HVAC pipework.:
Performed sections of glass fibers bonded with a heat-resistant resin, free from the shot and coarse fiber, light, damage-resistant, easy to handle, cut, and fit. The sections are split along their lengths to provide a hinge for ease of fitting. Aluglass facing ensures zero water vapor permeability, puncture resistance, and eliminates the need for external weather protection
View Product Datasheet
QR 11.50 – QR 125.00View Options -
Pipe Insulation – FSK Faced
KIMMCO-ISOVER’s produces a wide range of glass wool-based pre-formed pipe sections; designed specifically for the insulation of HVAC pipework.:
Faced with FSK – Pipe sections, with a factory-applied reinforced Aluminum foil covering (FSK) incorporating an overlap. Performed sections of glass fibers bonded with a heat-resistant resin, free from the shot and coarse fiber, light, damage-resistant, easy to handle, cut, and fit. The sections are split along their lengths to provide a hinge for ease of fitting.
Standard length: 1.2 MTR
View Product Datasheet
QR 14.00 – QR 195.00View Options -
Upright Sprinkler
The TYCO Series TY-B, 5.6 K-factor, Upright (TY315) Sprinklers are standard response, standard coverage, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, commercial occupancies such as banks, hotels, shopping malls, factories, refineries, and chemical plants.
- All hazard
- Discharges a hemispherical water spray pattern in the area beneath the sprinkler
- Small frame, narrow profile bulb
- Designed for use in light, ordinary, or extra hazard, commercial occupancies such as banks, hotels, shopping malls, factories, refineries, chemical plants, etc.
View Product Datasheet
-
Sidewall Sprinkler
The TYCO Series TY 5.6 K-factor, Horizontal Sidewall Sprinklers are standard response, standard coverage decorative 5 mm glass bulb type spray sprinklers designed for use in light and ordinary hazard, commercial occupancies such as banks, hotels, and shopping malls.
- Light hazard/Ordinary hazard
- Small frame
- Unique deflector design of the horizontal sidewall sprinkler results in smaller profile
- Designed for installation along a wall or the side of a beam just beneath a smooth ceiling
- Water discharge is directed primarily outward and downward in a quarter spherical pattern
- Sidewall sprinklers are often used in lieu of standard pendent or upright sprinklers due to building construction, economic considerations, or aesthetics
- Special deflector on the vertical sidewall sprinkler allows it to be installed in either a pendent or upright position
View Product Datasheet
-
Concealed Pendent Sprinkler
The TYCO Series RFII 5.6 K-factor, “Royal Flush II” Concealed Pendent Standard Response (5-mm bulb), is a decorative sprinkler featuring a flat cover plate designed to conceal the sprinkler. These sprinklers are optimal for architecturally sensitive areas such as hotel lobbies, office buildings, churches, and restaurants.
Each sprinkler includes a Cover Plate/Retainer Assembly and a Sprinkler/Support Cup Assembly.
View Product Datasheet
QR 32.00 – QR 48.00View Options -
Pendent Sprinkler
The TYCO Series TY-B, 5.6 K-factor, Pendent (TY325) Sprinklers are standard response, standard coverage, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, commercial occupancies such as banks, hotels, shopping malls, factories, refineries, and chemical plants.
View Product Datasheet TY3251
-
Surge Protector
DITEK’s DTK-HW Series of surge protective devices are designed and manufactured to meet the standards of the life safety industry and are widely used to protect fire alarm panels and other dedicated branch circuit loads.
View Product Datasheet