-
Rubber Insulation for Pipe -AP
ARMAFLEX AP RUBBER INSULATION
Armaflex AP Insulation/protection to control condensation, reduce energy loss and protect against frost on pipes, air ducts, vessels (incl. elbows, fittings, flanges, etc). Suitable for hot and cold water services, chilled water lines, heating systems, air conditioning ductwork, and refrigerated pipework. This grade of Insulation has in build micro ban antimicrobial technology & has better fire properties and complies with ASTM E-84 standard.
Standard Length: 2 Mtr pc Qty ,Price is per Mtr.
View Product Datasheet
QR 16.80 – QR 42.50View Options -
Rubber Insulation for Pipe – ...
ARMAFLEX RUBBER INSULATION CLASS O (AC)
Insulation/protection to control condensation, reduce energy loss and protect against frost on pipes, air ducts, vessels (incl. elbows, fittings, flanges, etc). Suitable for hot and cold water services, chilled water lines, heating systems, air conditioning, and refrigerated pipework
Note : Standard 2 meter length unit Qty , Price is per Mtr
View Product Datasheet
QR 2.50 – QR 16.22View Options -
Rubber Insulation for Pipe wi...
ARMAFLEX RUBBER INSULATION WITH ALUMINIUM FOIL Class O (AC)
Insulation/protection to control condensation, reduce energy loss and protect against frost on pipes, air ducts, vessels (incl. elbows, fittings, flanges, etc). Suitable for hot and cold water services, chilled water lines, heating systems, air conditioning ductwork, and refrigerated pipework. Factory-applied Reinforced Aluminium foil facing is applied on the facing of the insulation which will provide additional mechanical protection.
Note : Standard 2 Mtr length unit Qty ,Price is per Mtr
View Product Datasheet
QR 11.80 – QR 37.00View Options -
Armasound Duct Liner
Fiber free, super silent & microbe-resistant easy to apply acoustic insulation material, with very good sound absorption, damping, and barrier properties
View Product Datasheet
QR 97.00View Options -
Replacement Break Glass
Double Action Stations (Breakglass) requires the operator to strike the front-mounted hammer to break the glass and expose the recessed pull lever. The pull lever then operates as a single action station.
- Replacement break glass
- Non-Coded, Non-Addressable Manual Stations; 2099 Series Single and Double Action Operation
View Product Datasheet
QR 6.36View Options -
Fire Telephone
Firefighter telephone systems provide two-way communications for facilities where radio communications may not be available or are unreliable. They are typically used during active firefighting conditions, during a fire alarm investigation, or during fire alarm system inspection and test.
View Product Datasheet
QR 720.00View Options -
Double Action Pull Station
Manual release station, red housing with white letters and white pull lever Requires label kit
View Product Datasheet
QR 63.11View Options -
Coil Supervisory Module
Wired electrically before the actuator and located in the actuator wiring junction box. The connected RAC provides continuity supervision of the actuator coil and wiring and provides short circuit supervision to the coil supervision module.
View Product Datasheet
QR 90.00View Options -
Abort Switch
Single-gang size; includes 3 position contact block housing with 1 contact block UL, ULC, CSFM listed.
View Product Datasheet
-
Photoelectric Smoke Detector ...
Photoelectric smoke sensitivity is selectable at the fire alarm control panel. The host control panel automatically compensates for sensitivity shifts caused by contamination and automatically reports dirty devices
- Louvered design enhances smoke capture by directing flow to chamber
- Photoelectric sensor
- Photoelectric smoke sensitivity is selectable
- UL listed
View Product Datasheet FLKFDB0004
QR 125.00View Options -
Weatherproof Back Box for Pul...
Model: 2975-9211
- Weather-proof surface mount cast aluminum box,
- Suitable for outdoor applications
View Product Datasheet
QR 188.40View Options -
Multi-Candela Strobes
Multi-candela strobe with intensity selectable as: 15, 30, 75, or 110 candela; synchronized flash rate.
- Simplex fire alarm control panels with NACs selected to provide strobe synchronization or SmartSync two-wire control
- Ceiling mount strobes installed using standard single gang electrical boxes.
- Rear of housing does not extend into box
View Product Datasheet
QR 158.03View Options -
Rubber Insulation for Duct – AP
ARMAFLEX AP RUBBER INSULATION
Insulation/protection to control condensation, reduce energy loss and protect against frost for air ducts, vessels (incl. elbows, fittings, flanges etc). Suitable for air HVAC Ducts and is available in various thicknesses & options of with and without factory applied self-adhesive property. This grade of Insulation has in build microban antimicrobial technology & has better fire properties and complies to ASTM E-84 standard.
View Product Datasheet
QR 338.00View Options -
Flashing Strobe
TrueAlert ES addressable strobes are individually addressed visible notification appliances that receive power, supervision, and control signals from the Simplex fire alarm control panel providing IDNAC Signaling Line Circuits (SLCs).
View Product Datasheet
QR 141.60View Options -
Master Fire Telephone
Master Telephone with Control Module, three Class B telephone NACs Module and three Class B telephone NACs, one maximum per audio system.
View Product Datasheet
QR 1,404.00View Options