Water Flow Switch
The Potter VSR is a vane-type Waterflow switch with a non-corrosive insert for use on wet sprinkler systems.
- The Potter VSR is a vane type water flow switch with non-corrosive insert for use on wet sprinkler systems.
- It is UL Listed and FM Approved for use on steel pipe.
- Non – corrosive sleeve factory installed in saddle
View Product Datasheet
QR 342.00 – QR 435.00View Options -
Pressure Switch
The Potter PS10 Series Pressure Actuated Switches are designed for the detection of a water flow condition in automatic fire sprinkler systems of particular designs such as wet pipe systems with alarm check valves, dry pipe, preaction, or deluge valves.
View Product Datasheet
-
Ducted Split Air Conditioner
Low height air handler with side-discharge condensing unit Anti-freeze temperature sensor is provided on the coil against freezing during abnormal operating conditions.
Microprocessor Based Controller Filter drier is supplied loose as standard accessory Removable panels at the bottom of the unit that are provided for service access .
Quick connector for interconnecting communication cable (10 meter Long) from main controller to Controller User Interface Metallic Condenser fan blades and evaporator blower ensure safety & high durability .
High Pressure and Low Pressure safety controls are a standard feature on all the models
2T,2.5T,3T,3.5T Download Brochure
-
Wall Split Air Conditioner
Developed with environment friendly R410A refrigerant. R410A refrigerant is highly efficient and has an Ozone Depletion Potential (ODP) of 0.
Super Quiet: The in-built additional temperature sensor in the remote controller monitors the surrounding temperature. Therefore, the air-conditioner can adjust the room temperature more accurately and provide extra comfort to users.Quality rating : 6 star
- Inner-grooved copper tube
- Safety Design
- Leakage Detection
- Sleep Mode
- Vector Precision Air Supply
- T3 Tropical Compressor T3 Tropical Rotary compressor for high-efficiency and operation up to 52°C
Rust-proof - Flanging Processed Plate Metal
- Valve Protection Cover
Introduction Download Brochure
Performance table & selection Download Brochure
-
Tamper Switch
The OSYSU is used to monitor the open position of an OS&Y (outside screw and yoke) type gate valve.
The Model PCVS is a weather proof and tamper resistant switch for monitoring the open position of fire sprinkler control valves of the wall and yard post indicator and butterfly types
-
Upright Sprinkler
The TYCO Series TY-B, 5.6 K-factor, Upright (TY315) Sprinklers are standard response, standard coverage, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, commercial occupancies such as banks, hotels, shopping malls, factories, refineries, and chemical plants.
- All hazard
- Discharges a hemispherical water spray pattern in the area beneath the sprinkler
- Small frame, narrow profile bulb
- Designed for use in light, ordinary, or extra hazard, commercial occupancies such as banks, hotels, shopping malls, factories, refineries, chemical plants, etc.
View Product Datasheet
-
Sidewall Sprinkler
The TYCO Series TY 5.6 K-factor, Horizontal Sidewall Sprinklers are standard response, standard coverage decorative 5 mm glass bulb type spray sprinklers designed for use in light and ordinary hazard, commercial occupancies such as banks, hotels, and shopping malls.
- Light hazard/Ordinary hazard
- Small frame
- Unique deflector design of the horizontal sidewall sprinkler results in smaller profile
- Designed for installation along a wall or the side of a beam just beneath a smooth ceiling
- Water discharge is directed primarily outward and downward in a quarter spherical pattern
- Sidewall sprinklers are often used in lieu of standard pendent or upright sprinklers due to building construction, economic considerations, or aesthetics
- Special deflector on the vertical sidewall sprinkler allows it to be installed in either a pendent or upright position
View Product Datasheet
-
Concealed Pendent Sprinkler
The TYCO Series RFII 5.6 K-factor, “Royal Flush II” Concealed Pendent Standard Response (5-mm bulb), is a decorative sprinkler featuring a flat cover plate designed to conceal the sprinkler. These sprinklers are optimal for architecturally sensitive areas such as hotel lobbies, office buildings, churches, and restaurants.
Each sprinkler includes a Cover Plate/Retainer Assembly and a Sprinkler/Support Cup Assembly.
View Product Datasheet
QR 32.00 – QR 48.00View Options -
Pendent Sprinkler
The TYCO Series TY-B, 5.6 K-factor, Pendent (TY325) Sprinklers are standard response, standard coverage, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, commercial occupancies such as banks, hotels, shopping malls, factories, refineries, and chemical plants.
View Product Datasheet TY3251
-
-
Lug Style Butterfly Valves
Series BF-03 Full Lug Style Butterfly Valves are used in HVAC, irrigation, OEM, commercial, and institutional applications and wherever positive shutoff is required to control the flow of liquids, gases, and slurries. It features iron body construction, a stainless steel shaft, mounting pad for the 10-position lever, gear operator, or actuator.
View Product Datasheet