Carrier Wall split unit 1.5 t...
High Wall split unit , 2 TR / 6 star / R-410 a refrigerant / Rotary Compressor View Product Datasheet
QR 2,280.00 – QR 2,850.00View Options -
Carrier Wall split unit 2.5 ton
High Wall split unit Model No 38KHB030HN/42KHB030HN , 2.5TR / 6 star / R-410 a refrigerant / Rotary Compressor View Product Datasheet
QR 3,925.00View Options -
Water Flow Switch
The Potter VSR is a vane-type Waterflow switch with a non-corrosive insert for use on wet sprinkler systems.
- The Potter VSR is a vane type water flow switch with non-corrosive insert for use on wet sprinkler systems.
- It is UL Listed and FM Approved for use on steel pipe.
- Non – corrosive sleeve factory installed in saddle
View Product Datasheet
QR 342.00 – QR 435.00View Options -
Pressure Switch
The Potter PS10 Series Pressure Actuated Switches are designed for the detection of a water flow condition in automatic fire sprinkler systems of particular designs such as wet pipe systems with alarm check valves, dry pipe, preaction, or deluge valves.
View Product Datasheet
-
Ducted Split Air Conditioner
Low height air handler with side-discharge condensing unit Anti-freeze temperature sensor is provided on the coil against freezing during abnormal operating conditions.
Microprocessor Based Controller Filter drier is supplied loose as standard accessory Removable panels at the bottom of the unit that are provided for service access .
Quick connector for interconnecting communication cable (10 meter Long) from main controller to Controller User Interface Metallic Condenser fan blades and evaporator blower ensure safety & high durability .
High Pressure and Low Pressure safety controls are a standard feature on all the models
2T,2.5T,3T,3.5T Download Brochure
-
Wall Split Air Conditioner
Developed with environment friendly R410A refrigerant. R410A refrigerant is highly efficient and has an Ozone Depletion Potential (ODP) of 0.
Super Quiet: The in-built additional temperature sensor in the remote controller monitors the surrounding temperature. Therefore, the air-conditioner can adjust the room temperature more accurately and provide extra comfort to users.Quality rating : 6 star
- Inner-grooved copper tube
- Safety Design
- Leakage Detection
- Sleep Mode
- Vector Precision Air Supply
- T3 Tropical Compressor T3 Tropical Rotary compressor for high-efficiency and operation up to 52°C
Rust-proof - Flanging Processed Plate Metal
- Valve Protection Cover
Introduction Download Brochure
Performance table & selection Download Brochure
-
Tamper Switch
The OSYSU is used to monitor the open position of an OS&Y (outside screw and yoke) type gate valve.
The Model PCVS is a weather proof and tamper resistant switch for monitoring the open position of fire sprinkler control valves of the wall and yard post indicator and butterfly types
-
Upright Sprinkler
The TYCO Series TY-B, 5.6 K-factor, Upright (TY315) Sprinklers are standard response, standard coverage, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, commercial occupancies such as banks, hotels, shopping malls, factories, refineries, and chemical plants.
- All hazard
- Discharges a hemispherical water spray pattern in the area beneath the sprinkler
- Small frame, narrow profile bulb
- Designed for use in light, ordinary, or extra hazard, commercial occupancies such as banks, hotels, shopping malls, factories, refineries, chemical plants, etc.
View Product Datasheet
-
Sidewall Sprinkler
The TYCO Series TY 5.6 K-factor, Horizontal Sidewall Sprinklers are standard response, standard coverage decorative 5 mm glass bulb type spray sprinklers designed for use in light and ordinary hazard, commercial occupancies such as banks, hotels, and shopping malls.
- Light hazard/Ordinary hazard
- Small frame
- Unique deflector design of the horizontal sidewall sprinkler results in smaller profile
- Designed for installation along a wall or the side of a beam just beneath a smooth ceiling
- Water discharge is directed primarily outward and downward in a quarter spherical pattern
- Sidewall sprinklers are often used in lieu of standard pendent or upright sprinklers due to building construction, economic considerations, or aesthetics
- Special deflector on the vertical sidewall sprinkler allows it to be installed in either a pendent or upright position
View Product Datasheet
-
Abort Switch
Single-gang size; includes 3 position contact block housing with 1 contact block UL, ULC, CSFM listed.
View Product Datasheet
QR 381.00View Options -
Basic Control Unit Modules
4010 control panel Basic Control Unit with 2 x 40 LCD Operator Interface and (1) Two-loop Isolated IDNet+ Communications Channel, Class A or Class B operation, with support for up to 248 addressable IDNet points
View Product Datasheet
QR 4,500.00 – QR 5,262.00View Options -
Switch Input Module
These remote annunciator graphic control modules complement Simplex 4007ES, 4010ES, 4100ES, and 4100U (and other installed legacy panels) by providing LED/lamp/relay drivers and switch inputs to allow custom graphic displays to be designed for specific facility requirements, such as for smoke control (UUKL) systems.
View Product Datasheet
-
Multi-Candela Strobes
Multi-candela strobe with intensity selectable as: 15, 30, 75, or 110 candela; synchronized flash rate.
- Simplex fire alarm control panels with NACs selected to provide strobe synchronization or SmartSync two-wire control
- Ceiling mount strobes installed using standard single gang electrical boxes.
- Rear of housing does not extend into box
View Product Datasheet
-
Bladder Expansion Tank
Intended for use in hydronic heating systems, these tanks accept the expanded volume of hot water keeping the system pressure below the relief valve setting, thus preventing dangerous pressure build-up.
View Product Datasheet
QR 12,200.00 – QR 13,500.00View Options -
Concealed Pendent Sprinkler
The TYCO Series RFII 5.6 K-factor, “Royal Flush II” Concealed Pendent Standard Response (5-mm bulb), is a decorative sprinkler featuring a flat cover plate designed to conceal the sprinkler. These sprinklers are optimal for architecturally sensitive areas such as hotel lobbies, office buildings, churches, and restaurants.
Each sprinkler includes a Cover Plate/Retainer Assembly and a Sprinkler/Support Cup Assembly.
View Product Datasheet
QR 32.00 – QR 48.00View Options -
Pendent Sprinkler
The TYCO Series TY-B, 5.6 K-factor, Pendent (TY325) Sprinklers are standard response, standard coverage, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, commercial occupancies such as banks, hotels, shopping malls, factories, refineries, and chemical plants.
View Product Datasheet TY3251
-
Flashing Strobe
TrueAlert ES addressable strobes are individually addressed visible notification appliances that receive power, supervision, and control signals from the Simplex fire alarm control panel providing IDNAC Signaling Line Circuits (SLCs).
View Product Datasheet