-
OS and Y Gate Valves
Mueller 2300 Series Resilient Wedge Gate Valves are intended for use in potable water distribution or fire protection systems.
- UL 262 Listed and FM 1120/1130 Approved and certified to ANSI/NSF 61 & 372
- Epoxy Coated interior and exterior surfaces
- Outside Screw & Yoke (O.S.&Y)
- Adjustable packing
- Rubber encapsulated iron wedge
- Hand wheel – open left or open right
View Product Datasheet
-
Pipe Insulation – Aluglass Faced
KIMMCO-ISOVER’s produces a wide range of glass wool-based pre-formed pipe sections; designed specifically for the insulation of HVAC pipework.:
Performed sections of glass fibers bonded with a heat-resistant resin, free from the shot and coarse fiber, light, damage-resistant, easy to handle, cut, and fit. The sections are split along their lengths to provide a hinge for ease of fitting. Aluglass facing ensures zero water vapor permeability, puncture resistance, and eliminates the need for external weather protection
View Product Datasheet
QR 11.50 – QR 125.00View Options -
Pipe Insulation – FSK Faced
KIMMCO-ISOVER’s produces a wide range of glass wool-based pre-formed pipe sections; designed specifically for the insulation of HVAC pipework.:
Faced with FSK – Pipe sections, with a factory-applied reinforced Aluminum foil covering (FSK) incorporating an overlap. Performed sections of glass fibers bonded with a heat-resistant resin, free from the shot and coarse fiber, light, damage-resistant, easy to handle, cut, and fit. The sections are split along their lengths to provide a hinge for ease of fitting.
Standard length: 1.2 MTR
View Product Datasheet
QR 14.00 – QR 195.00View Options -
Upright Sprinkler
The TYCO Series TY-B, 5.6 K-factor, Upright (TY315) Sprinklers are standard response, standard coverage, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, commercial occupancies such as banks, hotels, shopping malls, factories, refineries, and chemical plants.
- All hazard
- Discharges a hemispherical water spray pattern in the area beneath the sprinkler
- Small frame, narrow profile bulb
- Designed for use in light, ordinary, or extra hazard, commercial occupancies such as banks, hotels, shopping malls, factories, refineries, chemical plants, etc.
View Product Datasheet
-
Sidewall Sprinkler
The TYCO Series TY 5.6 K-factor, Horizontal Sidewall Sprinklers are standard response, standard coverage decorative 5 mm glass bulb type spray sprinklers designed for use in light and ordinary hazard, commercial occupancies such as banks, hotels, and shopping malls.
- Light hazard/Ordinary hazard
- Small frame
- Unique deflector design of the horizontal sidewall sprinkler results in smaller profile
- Designed for installation along a wall or the side of a beam just beneath a smooth ceiling
- Water discharge is directed primarily outward and downward in a quarter spherical pattern
- Sidewall sprinklers are often used in lieu of standard pendent or upright sprinklers due to building construction, economic considerations, or aesthetics
- Special deflector on the vertical sidewall sprinkler allows it to be installed in either a pendent or upright position
View Product Datasheet
-
Cylinder Mounting Bracket
Vertical bracketing of the PCL-160, PCL-300 and PCL-460 is provided by the Model MB-15 bracket kit . Vertical bracketing of the PCL-600 is provided by the Model MB-1 bracket kit . These kits must be ordered separately with each cylinder/valve assembly. Cylinder installation instructions are provided in the installation section of this manual.
- Cylinder Bracket
- These kits must be ordered separately with each cylinder/valve assembly
- Cylinder installation instructions are provided in the installation section of this manual.
View Product Datasheet
-
Nozzle
Nozzles have been developed for appliance, plenum, and duct applications. All nozzles have a specific flow point value and are supplied with metal blow-off caps to prevent clogging. Each nozzle is stamped with the model number.
View Product Datasheet
-
Agent Cylinder With Valve
The cylinder is manufactured, tested, and meets DOT requirements. Cylinders come pre-filled with extinguishing agent and are charged with dry nitrogen to a pressure
- Meets the requirements of the Building Officials and Code Administrators (BOCA)
- Meets the requirements of the International Building Code (IBC)
- Approved by the City of New York Material and Equipment
View Product Datasheet
QR 2,445.00View Options -
Abort Switch
Single-gang size; includes 3 position contact block housing with 1 contact block UL, ULC, CSFM listed.
View Product Datasheet
QR 381.00View Options -
Basic Control Unit Modules
4010 control panel Basic Control Unit with 2 x 40 LCD Operator Interface and (1) Two-loop Isolated IDNet+ Communications Channel, Class A or Class B operation, with support for up to 248 addressable IDNet points
View Product Datasheet
QR 4,500.00 – QR 5,262.00View Options -
Switch Input Module
These remote annunciator graphic control modules complement Simplex 4007ES, 4010ES, 4100ES, and 4100U (and other installed legacy panels) by providing LED/lamp/relay drivers and switch inputs to allow custom graphic displays to be designed for specific facility requirements, such as for smoke control (UUKL) systems.
View Product Datasheet
-
Multi-Candela Strobes
Multi-candela strobe with intensity selectable as: 15, 30, 75, or 110 candela; synchronized flash rate.
- Simplex fire alarm control panels with NACs selected to provide strobe synchronization or SmartSync two-wire control
- Ceiling mount strobes installed using standard single gang electrical boxes.
- Rear of housing does not extend into box
View Product Datasheet
-
DZR Brass Float Valve
DZR Brass Float Valve. Supplied with locknut. Machined fixed flange on the valve body. No jam single lever action.
View Product Datasheet
-
Concealed Pendent Sprinkler
The TYCO Series RFII 5.6 K-factor, “Royal Flush II” Concealed Pendent Standard Response (5-mm bulb), is a decorative sprinkler featuring a flat cover plate designed to conceal the sprinkler. These sprinklers are optimal for architecturally sensitive areas such as hotel lobbies, office buildings, churches, and restaurants.
Each sprinkler includes a Cover Plate/Retainer Assembly and a Sprinkler/Support Cup Assembly.
View Product Datasheet
QR 32.00 – QR 48.00View Options -
Pendent Sprinkler
The TYCO Series TY-B, 5.6 K-factor, Pendent (TY325) Sprinklers are standard response, standard coverage, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, commercial occupancies such as banks, hotels, shopping malls, factories, refineries, and chemical plants.
View Product Datasheet TY3251
-
Flashing Strobe
TrueAlert ES addressable strobes are individually addressed visible notification appliances that receive power, supervision, and control signals from the Simplex fire alarm control panel providing IDNAC Signaling Line Circuits (SLCs).
View Product Datasheet