CO2 Fire Extinguisher
- British Standards Institution – BSI approval.
- Suitable for Class B & Electrical Hazards.
- High quality and good value.
- Colour coded for instant recognition.
- Available in aluminum and lightweight steel.
- Easy to use and leaves no messy residue.
- ISO 9001 Certified Quality System by QAS Australia.
- EN3 approved
- Cylinder Test Pressure: 250 Bar
QCD Approved
QR 288.00View Options -
Discharge Nozzle Brass
FM-200® is distributed within the protected area by the discharge nozzle which is sized to ensure the correct flow of agent for the risk. Nozzles are supplied as standard in Brass as BSPP or NPT with Stainless Steel as an option
View Product Datasheet
-
Upright Sprinkler
The TYCO Series TY-B, 5.6 K-factor, Upright (TY315) Sprinklers are standard response, standard coverage, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, commercial occupancies such as banks, hotels, shopping malls, factories, refineries, and chemical plants.
- All hazard
- Discharges a hemispherical water spray pattern in the area beneath the sprinkler
- Small frame, narrow profile bulb
- Designed for use in light, ordinary, or extra hazard, commercial occupancies such as banks, hotels, shopping malls, factories, refineries, chemical plants, etc.
View Product Datasheet
-
Sidewall Sprinkler
The TYCO Series TY 5.6 K-factor, Horizontal Sidewall Sprinklers are standard response, standard coverage decorative 5 mm glass bulb type spray sprinklers designed for use in light and ordinary hazard, commercial occupancies such as banks, hotels, and shopping malls.
- Light hazard/Ordinary hazard
- Small frame
- Unique deflector design of the horizontal sidewall sprinkler results in smaller profile
- Designed for installation along a wall or the side of a beam just beneath a smooth ceiling
- Water discharge is directed primarily outward and downward in a quarter spherical pattern
- Sidewall sprinklers are often used in lieu of standard pendent or upright sprinklers due to building construction, economic considerations, or aesthetics
- Special deflector on the vertical sidewall sprinkler allows it to be installed in either a pendent or upright position
View Product Datasheet
QR 29.00View Options -
-
-
Fire Extinguishers
Fire extinguishers are ideal for use against class A, B & C fires. Highly effective against petrol and volatile liquids which makes them ideal for vehicle protection. A good all-rounder makes dry powder an excellent choice for both industrial and domestic premises.
- EN3 approved.
- Suitable for Class A, B, C & electrical hazards.
- Ideal for industrial, commercial and domestic environment.
- High quality and good value.
- Color-coded for instant recognition.
- All units tested by electronic leak detection.
- Operated effectively at both high and low temperature
View Product Datasheet Dry Powder Type Water Type
-
Abort Switch
Single-gang size; includes 3 position contact block housing with 1 contact block UL, ULC, CSFM listed.
View Product Datasheet
QR 381.00View Options -
Basic Control Unit Modules
4010 control panel Basic Control Unit with 2 x 40 LCD Operator Interface and (1) Two-loop Isolated IDNet+ Communications Channel, Class A or Class B operation, with support for up to 248 addressable IDNet points
View Product Datasheet
QR 4,500.00 – QR 5,262.00View Options -
Switch Input Module
These remote annunciator graphic control modules complement Simplex 4007ES, 4010ES, 4100ES, and 4100U (and other installed legacy panels) by providing LED/lamp/relay drivers and switch inputs to allow custom graphic displays to be designed for specific facility requirements, such as for smoke control (UUKL) systems.
View Product Datasheet
-
Multi-Candela Strobes
Multi-candela strobe with intensity selectable as: 15, 30, 75, or 110 candela; synchronized flash rate.
- Simplex fire alarm control panels with NACs selected to provide strobe synchronization or SmartSync two-wire control
- Ceiling mount strobes installed using standard single gang electrical boxes.
- Rear of housing does not extend into box
View Product Datasheet
QR 180.00View Options -
Container Label
The container label detailsthe weight of NOVEC™ 1230 contained, empty weight, fill density and charge date.
View Product Datasheet
QR 286.00View Options -
Hose Male Adaptor
The male pilot hose connector is used to connect two pilot hoses together for systems where a second container of a different size is used to protect a different enclosure.
View Product Datasheet
-
Manual/Pneumatic Actuator
This Actuator is Used for mechanical or pneumatic operating system at the container position and is fitted to the top of the valve assembly or removable electrical actuator.
View product Datasheet
QR 334.00View Options -
Manifold Inlet
Manifold inlets are available for the construction of system manifolds. Threaded Inlet for Manifolds
View Product Datasheet
-
Roof Exhaust Downblast
FCS -D (Direct drive) & FCS -B (Belt drive) fans are ideal for general purpose exhaust applications including bathrooms, garages, general kitchen areas, offices, churches, dormitories, factories, large warehouses, and other relatively clean air applications. They feature a weather-resistant, seamless spun aluminum housing which works in conjunction with a patented wheel design and deeply spun inlets to provide smooth quiet airflow through the ventilator. The centrifugal wheels are aluminum, non-overloading, backward inclined, robotically welded, and dynamically balanced
View Product Datasheet
-
Plate Mounted Axial Fans
The QCM series are axial fans suitable for application on wall or panel in residential, commercial and industrial building.
View Product Datasheet
-
Gravity Shutters
Gravity Shutters avoids heat loss and entry of wind, rain, and birds. The fins of the shutter are opened by the airflow when the fan is working and they close down by gravity when the fan is switched off.
View Product Datasheet
-
Concealed Pendent Sprinkler
The TYCO Series RFII 5.6 K-factor, “Royal Flush II” Concealed Pendent Standard Response (5-mm bulb), is a decorative sprinkler featuring a flat cover plate designed to conceal the sprinkler. These sprinklers are optimal for architecturally sensitive areas such as hotel lobbies, office buildings, churches, and restaurants.
Each sprinkler includes a Cover Plate/Retainer Assembly and a Sprinkler/Support Cup Assembly.
View Product Datasheet
QR 32.00 – QR 48.00View Options -
Pendent Sprinkler
The TYCO Series TY-B, 5.6 K-factor, Pendent (TY325) Sprinklers are standard response, standard coverage, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, commercial occupancies such as banks, hotels, shopping malls, factories, refineries, and chemical plants.
View Product Datasheet TY3251
-
Valve Single Tank Adaptors
When a single 343 litre container is being used without a manifold, three swivel adaptors are available for connection to the discharge outlet
View Product Datasheet
QR 657.00View Options -
-
Centrifugal Roof Extractors
Centrifugal roof fans are designed for direct or ducted ventilation in residential, commercial, and industrial buildings. they are designed for easy installation, high-efficiency low noise levels. The motor is outside the airflow, this allows the fan to exhaust clean or slightly dusty air with temperature
View Product Datasheet
QR 2,296.00View Options