-
Grooved Check Valve
The TYCO Model CV-1F Grooved End Swing Check Valves are compact and rugged swing-type units that allow water flow in one direction and prevent flow in the opposite direction.
View Product Datasheet
QR 525.00 – QR 1,245.00View Options -
Water Flow Switch
The Potter VSR is a vane-type Waterflow switch with a non-corrosive insert for use on wet sprinkler systems.
- The Potter VSR is a vane type water flow switch with non-corrosive insert for use on wet sprinkler systems.
- It is UL Listed and FM Approved for use on steel pipe.
- Non – corrosive sleeve factory installed in saddle
View Product Datasheet
-
Pressure Switch
The Potter PS10 Series Pressure Actuated Switches are designed for the detection of a water flow condition in automatic fire sprinkler systems of particular designs such as wet pipe systems with alarm check valves, dry pipe, preaction, or deluge valves.
View Product Datasheet
QR 230.00View Options -
Wet Alarm Valves
The TYCO Model Alarm Check Valves are intended for use in wet pipe (automatic sprinkler) fire protection systems.
View Product Datasheet
QR 1,213.00 – QR 2,685.00View Options -
-
FIVC Expansion Joint -Threaded
FIVC Expansion Joint is designed to be installed into pipelines for the purpose to avoid damage caused by stretching, compressing, deflecting, or displacing pipes.
View Product Datasheet EPDM02
QR 43.00View Options -
FIVC Butterfly Valve – ...
FIVC Wafer Butterfly Valve is designed to be installed in pipelines for isolating or regulating purposes. With its high-quality rotational disc, the valve features a quick shut-off function.
View Product Datasheet
QR 1,012.00 – QR 5,671.00View Options -
FIVC Butterfly Valve – ...
FIVC Lugged Butterfly Valve with its replaceable seat is designed to be installed in pipelines for isolating or regulating purposes. With its high-quality rotational disc, the valve features a quick shut-off function.
View Product Datasheet
QR 1,709.00 – QR 5,031.00View Options -
Flowcon Bronze Y Strainers
FIVC Y-Strainer is designed to collect and prevent solid impurities from entering the pipeline that can cause malfunction and damage to the most sensitive plant components such as pumps, control valves, flow, and heat meters.
View Product Datasheet 260121
QR 27.00View Options -
Rubber Insulation For Duct – ...
ARMAFLEX CLASS O (AC) RUBBER INSULATION
Insulation/protection to control condensation, reduce energy loss and protect against frost for air ducts, vessels (incl. elbows, fittings, flanges, etc). Suitable for air HVAC Ducts and is available in various thicknesses & options with and without factory-applied self-adhesive property.
View Product Datasheet
-
Rubber Insulation for Pipe – ...
ARMAFLEX RUBBER INSULATION CLASS O (AC)
Insulation/protection to control condensation, reduce energy loss and protect against frost on pipes, air ducts, vessels (incl. elbows, fittings, flanges, etc). Suitable for hot and cold water services, chilled water lines, heating systems, air conditioning, and refrigerated pipework
Note : Standard 2 meter length unit Qty , Price is per Mtr
View Product Datasheet
-
Rubber Insulation for Pipe -AP
ARMAFLEX AP RUBBER INSULATION
Armaflex AP Insulation/protection to control condensation, reduce energy loss and protect against frost on pipes, air ducts, vessels (incl. elbows, fittings, flanges, etc). Suitable for hot and cold water services, chilled water lines, heating systems, air conditioning ductwork, and refrigerated pipework. This grade of Insulation has in build micro ban antimicrobial technology & has better fire properties and complies with ASTM E-84 standard.
Standard Length: 2 Mtr pc Qty ,Price is per Mtr.
View Product Datasheet
QR 10.15 – QR 31.53View Options -
Tamper Switch
The OSYSU is used to monitor the open position of an OS&Y (outside screw and yoke) type gate valve.
The Model PCVS is a weather proof and tamper resistant switch for monitoring the open position of fire sprinkler control valves of the wall and yard post indicator and butterfly types
QR 210.00View Options -
Upright Sprinkler
The TYCO Series TY-B, 5.6 K-factor, Upright (TY315) Sprinklers are standard response, standard coverage, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, commercial occupancies such as banks, hotels, shopping malls, factories, refineries, and chemical plants.
- All hazard
- Discharges a hemispherical water spray pattern in the area beneath the sprinkler
- Small frame, narrow profile bulb
- Designed for use in light, ordinary, or extra hazard, commercial occupancies such as banks, hotels, shopping malls, factories, refineries, chemical plants, etc.
View Product Datasheet
-
Sidewall Sprinkler
The TYCO Series TY 5.6 K-factor, Horizontal Sidewall Sprinklers are standard response, standard coverage decorative 5 mm glass bulb type spray sprinklers designed for use in light and ordinary hazard, commercial occupancies such as banks, hotels, and shopping malls.
- Light hazard/Ordinary hazard
- Small frame
- Unique deflector design of the horizontal sidewall sprinkler results in smaller profile
- Designed for installation along a wall or the side of a beam just beneath a smooth ceiling
- Water discharge is directed primarily outward and downward in a quarter spherical pattern
- Sidewall sprinklers are often used in lieu of standard pendent or upright sprinklers due to building construction, economic considerations, or aesthetics
- Special deflector on the vertical sidewall sprinkler allows it to be installed in either a pendent or upright position
View Product Datasheet
QR 29.00View Options -
Butterfly Valve Grooved End
The TYCO Models BFV-300 and BFV300C Grooved End Butterfly Valves are indicating type valves designed for use in fire protection systems where a visual indication of open or closed valve condition is required
- Designed for use in fire protection systems
- UL and ULC Listed
- FM Approved
View Product Datasheet
QR 756.00 – QR 1,435.00View Options -
Rubber Lined Split Clamps
A Convenient and effective means of preventing crushing of pipe supports of Chilled Water, Condenser water and Domestic hot/cold water installations. Available for any pipe size and insulation thickness,
View Product Datasheet
QR 1.00 – QR 4.55View Options -
Balancing Valves Variable Ori...
FIVC Static Balancing Valve is designed with integrated pressure probes to determine the flow rate through the integrated fixed orifice.
View Product Datasheet
-
Trim Vertical Closed Drain Co...
The TYCO Series “Royal Flush II” Concealed Pendent Sprinklers Quick Response (3-mm bulb) and Standard Response (5-mm bulb), are decorative sprinklers featuring a flat cover plate designed to conceal the sprinkler.
The TYCO Model RC-1 Retard Chamber is required in installations that will be subject to pressure variations, as are generally associated with public water supplies, in order to help prevent false alarms.
- Quick & Standard Response, Standard Coverage
- Designed to conceal the sprinkler.
- UL Listed and FM Approval
View Product Datasheet RFII
QR 1,260.00View Options -
Wet Chemical Fire Extinguishers
Wet chemical extinguishers are the best restaurant kitchen appliance hand portable fire extinguishers.
- All metal valve construction
- Swivel connection on hose allows nozzle to be oriented for proper use
- Nozzle grip design with 45° angle for easy “overhead” application
- Low PH agent discharged as fine mist helps prevent grease splash and re-flash while cooling the appliance
- Precise extinguishing agent application no dry chemical to clean up
- Excellent for use on all cooking appliances including solid fuel charbroilers
- Tested on commercial deep fat fryers to ul 711 test protocol and safe to use on class c fires
- Class 2a rated to meet fire code occupancy hazard requirements
- Bar coded and bi-lingual labels
View Product Datasheet
QR 280.00View Options -
Concealed Pendent Sprinkler
The TYCO Series RFII 5.6 K-factor, “Royal Flush II” Concealed Pendent Standard Response (5-mm bulb), is a decorative sprinkler featuring a flat cover plate designed to conceal the sprinkler. These sprinklers are optimal for architecturally sensitive areas such as hotel lobbies, office buildings, churches, and restaurants.
Each sprinkler includes a Cover Plate/Retainer Assembly and a Sprinkler/Support Cup Assembly.
View Product Datasheet
-
Pendent Sprinkler
The TYCO Series TY-B, 5.6 K-factor, Pendent (TY325) Sprinklers are standard response, standard coverage, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, commercial occupancies such as banks, hotels, shopping malls, factories, refineries, and chemical plants.
View Product Datasheet TY3251
-
Deluge Valve, Diaphragm Style
The DV-5 Deluge Valve is a diaphragm style valve that depends upon water pressure in the Diaphragm Chamber to hold the Diaphragm closed against the water supply pressure. These valves are to be used only for hydraulically calculated systems.
View Product Datasheet
QR 3,882.00View Options -
Static Balancing Valve
FIVC Static Balancing Valve is designed with integrated pressure probes to determine the flow rate through the integrated fixed orifice. The valve offers an accuracy of ± 5 pct. on all settings, for precise flow regulation
View Product Datasheet
QR 105.00View Options